{"product_id":"panasonic-heat-pump-rear-installation-plate-acxh36-00650-cs-z42xkrw","title":"Panasonic Heat Pump Rear Installation Plate ACXH36-00650 – CS-Z42XKRW","description":"\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eGenuine Panasonic indoor installation plate ACXH36-00650 for mounting the indoor heat pump unit to the wall. This rear mounting bracket supports the indoor unit and provides the correct attachment points for installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePart number: ACXH36-00650\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eSearch reference: ACXH3600650\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eBrand: Panasonic\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003ePart type: indoor unit rear installation plate \/ wall mounting bracket\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eGenuine Panasonic replacement installation plate.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounts behind the indoor wall unit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eReplaces a missing, bent or damaged mounting plate.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eProvides the specified mounting points for the indoor unit.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eCommon Signs You May Need a Replacement\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInstallation plate is missing.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePlate is bent, corroded or damaged.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMounting hooks or attachment points are distorted.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe indoor unit cannot engage securely with the existing plate.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLoose wall fixings or an unsuitable wall structure must also be corrected. Replacing the plate alone will not resolve these problems.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eCompatibility – check model label and compare values\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with the following model:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCS-Z42XKRW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCheck the complete indoor unit model number before ordering. Compare the plate shape, hook positions and fixing layout with the original installation plate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation Guide\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eInstallation should be completed by a qualified heat pump installer using the Panasonic installation instructions for CS-Z42XKRW.\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIsolate the electricity supply before starting work.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIf replacing a plate on an installed unit, have the installer safely support and release the indoor unit. Do not strain the refrigerant pipes, drain hose or electrical wiring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect the wall and select suitable structural fixing points. Use fixings appropriate for the wall material and appliance load.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePosition and level the installation plate. Follow Panasonic’s specified ceiling clearances, side clearances, fixing positions and pipe-hole location.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSecure the plate firmly without bending or distorting it.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eArrange the pipes, wiring and drain hose according to the installation manual. Maintain the required drainage fall and avoid kinks.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEngage the indoor unit with the plate’s upper hooks, then secure the lower attachment points as instructed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCheck that the unit is firmly attached and test drainage and operation before completing the installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cspan\u003eDo not disconnect refrigerant pipework unless the work is carried out by a qualified refrigeration technician. Mounting screws and wall anchors should not be assumed included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFor compatibility assistance, email your indoor unit model label to \u003c\/span\u003e\u003ca href=\"mailto:info@homeappliancesonline.co.nz\"\u003e\u003cspan\u003einfo@homeappliancesonline.co.nz\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePanasonic CS-Z42XKRW Installation Plate ACXH36-00650\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCS-RZ25WKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ35WKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ42WKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ50WKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ25XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ35XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ42XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-RZ50XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z20AKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z25AKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z25AKRW-1\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z35AKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z42AKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z50AKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z50AKRW-1\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z20XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z25XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z25XKRW-1\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z35XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z42XKRW\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eCS-Z50XKRW\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eGenuine Panasonic rear installation plate ACXH36-00650 for CS-Z42XKRW heat pumps. Replacement indoor wall mounting bracket. Professional fitting recommended.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Home Appliances Online","offers":[{"title":"Default Title","offer_id":67756365480226,"sku":"HA00650","price":45.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0726\/0504\/0930\/files\/ACXH36-00650.png?v=1794272541","url":"https:\/\/www.homeappliancesonline.co.nz\/products\/panasonic-heat-pump-rear-installation-plate-acxh36-00650-cs-z42xkrw","provider":"Home Appliances Online","version":"1.0","type":"link"}